User Manual
Manual-FCHA1-Rev1009.pdf Page 4 of 9 www.kbcnetworks.com
Copyright © KBC Networks Ltd
Connectors:
DC or AC Power Supply between 12V and 24V can be used on this product.
• DC:
+: +12VDC~+24VDC
-: Power Supply Ground
• AC:
There is no difference between +/-; the power supply can be connected into
the device directly.
FIB: Fiber Optic connector.
GND: Ground pin.
LEDs Definition:
POW: Power Supply. On if power input is in OK.
FIB: Fiber Link. Off if the link is in OK.
V: Video. On if video input is in OK.
C1: Channel 1 Contact Closure input. On if the contact input is closed.
C2: Channel 1 Contact Closure output. On if the contact output is closed.
C3: Channel 2 Contact Closure input. On if the contact input is closed.
C4: Channel 2 Contact Closure output. On if the contact output is closed.
The other is reserved.